KRIWAN INT69 Y Diagnose Article-Nr.: 22 A 630 S21, 31 A 630 S21
Product details :
- Application : Compressors with direction of rotation essential for function
- Functions : Motor temperature static, Motor temperature dynamic, Short circuit, short cycling, Lock-out, Phase monitoring, phase sequence, phase failure
- Supply voltage : AC 24-240V
- Permitted ambient temperature : -30...+70°C
- Temperature measuring circuits: Type : 1-2 AMS sensors in series alternative 1-9 PTC sensors acc. to DIN 44081, DIN 44082 in series
- Temperature measuring circuits: R_25, total : <1.8kΩ
- Temperature measuring circuits: R_trip, static : 4.5kΩ ±20%
- Temperature measuring circuits: R_reset : 2.75kΩ ±20%
- Temperature measuring circuits: Max. length connection line : 30m
- Short circuit monitoring system PTC : Typically <30Ω
- Motor voltage : 3 AC 50/60Hz 200-690V ±10%
- Phase monitoring: Phase sequence : Active about 1s after motor start for about 5s
- Phase monitoring: Phase failure : Active about 1s after the motor start until the motor stop
- Phase monitoring: Inactive : After motor stop for approx. 20s
- Switching frequency overstepping : 3 switch-offs in 30s
- Operating with frequency converters : Not suitable
- Reset delay: Motor temperature static : 5min ±1min
- Reset delay: Motor temperature dynamic : 5min ±1min, 60min ±12min, Locked
- Reset delay: Switching frequency overstepping : 5min ±1min
- Reset delay: Incorrect phase sequence : Locked
- Reset delay: Phase failure : Locked
- Resetting the lock or the reset delay : Main reset >5s only possible if there is no error current
- Relay: Connection : AC 240V 2.5A C300 at least AC/DC 24V 20mA, AC 240V 2.5A C300 at least AC/DC 100mV 0.5mA
- Relay: Mechanical service life : Approx. 1 million switching cycles
- Interface : Diagnose port (DP)
- Protection class acc. To EN 60529 : IP00
- Connection type : 6.3mm flat plugs
- Housing material : PA glass-fibre-reinforced
- Mounting : Screw mounted
- Dimensions : Refer to dimensions in mm
- Weight : Approx. 200g
- Check base : EN 61000-6-2, EN 61000-6-3 EN 61010-1 Overvoltage category II Pollution level 2
- Approval : UL File No. E75899 cURus