KIDDEFIRE GRAVINER
OMD MK6 - The detector is mounted on the engine with the detector sample pipe protruding inside the crank space. The air in the crank space is drawn into the detector by a fan in each detector. The oil mist level is measured by the detector using light scatter inside the detector sample chamber. The Control Panel uses an RS485 serial communication's connection to request the oil mist level and status from the detector. The oil mist level is compared with the alarm levels set in the Control Panel. If the measured oil mist level is above the pre defined alarm level the common alarm and shutdown alarm relays are activated.
The system is also monitored to ensure it is functioning correctly. Any failures are indicated as a fault on the Control Panel and the fault relay activated. Up to eight engines may be connected to a Control Panel with a maximum of 64 detectors.
SYSTEM COMPONENTS
Control Panel
(Bulkhead Mount P/N1-53836-K170)
(Flush Mount P/N 1-53836-K206)
Straight Cable Connector
(P/N 1-43682-K108-xx)
Right Angle Cable Connector
(P/N 1-43682-K109-xx)
Complete Detector Head
(P/N 1-E3561-301)
Junction Box
(M20 cable P/N 1-53836-K224-xx)
(M25 cable P/N 1-D4720-001-xx)
Replacement Detector Head
(P/N 1-D5622-001)
P/N 1-44782-K183
P/N 1-44782-K183X (non GL classed vessels)
Old Interface Board
P/N 1-44782-K085
EEPROM
P/N 1-44782-K182
MK6 Replacement EEPROM 1-44782-K182
Etc