  • KRIWAN INT69 YL Diagnose Article-Nr.: 25 A 497

KRIWAN INT69 YL Diagnose Article-Nr.: 25 A 497

Update Terakhir
:
27 / 02 / 2024
Min. Pembelian
:
1 Unit

Harga

CALL
Beyond Imagination Vendor…

Detail KRIWAN INT69 YL Diagnose Article-Nr.: 25 A 497

KRIWAN INT69 YL Diagnose Article-Nr.: 25 A 497

 

Product details : 

  • Application : Compressors with direction of rotation essential for function and oil management
  • Function : Motor temperature static, Motor temperature dynamic, Oil temperature, Short circuit, short cycling, Phase monitoring, phase sequence, phase asymmetry, Lock-out, operating recognition
  • Supply voltage : AC/DC 24-240V
  • Permitted ambient temperature : -30...+70°C
  • Temperature measuring circuits: Type : 1-2 AMS sensors in series alternative 1-9 PTC sensors acc. to DIN44081, DIN44082 in series
  • Temperature measuring circuits: R_25, total : <1.8kΩ
  • Temperature measuring circuits: R_trip, static : 4.5kΩ ±20%
  • Temperature measuring circuits: R_reset : 2.75kΩ ±20%
  • Temperature measuring circuits: Max. length connection line : 30m
  • Short circuit monitoring system PTC : Typically <30Ω
  • Input oil flow oil level and oil filter soiling: Designed for Potential-free normally open contact (typ. 3.3V, 1mA)
  • Input oil flow oil level and oil filter soiling: Max. length connection line : 30m
  • Motor voltage : 3 AC 20-100Hz 80-690V ±10%
  • Phase monitoring: Phase sequence : Active about 1s after motor start for about 5s
  • Phase monitoring: Phase failure : Active about 1s after the motor start until the motor stop
  • Phase monitoring: Inactive : After motor stop for approx. 10s
  • Phase monitoring: Phase asymmetry : Active about 1s after the motor start until the motor stop
  • Switching frequency overstepping : 3 switch-offs in 60s or 10switch-offs in 1h
  • Operating with frequency converters : Suitable
  • Reset delay: Motor temperature static : 5min ±1min
  • Reset delay: Motor temperature dynamic : 10min ±2min, 60min ±12min, Locked
  • Reset delay: Switching frequency overstepping : 5min ±1min, 30min ±6min
  • Reset delay: Incorrect phase sequence : Locked
  • Reset delay: Oil temperature : Undelayed
  • Reset delay: Phase asymmetry : 5min ±1min, Verriegelt
  • Reset delay: Oil flow : 5min ±1min, Verriegelt
  • Reset delay: Oil filter : Locked
  • Reset delay: Oil level : Locked
  • Resetting the lock or the reset delay : Main reset >5s or reset by keyboard only possible if there is no error current
  • External button: Designed for : Potential-free normally open contact (typ. 3.3V, 1mA)
  • External button: Max. length connection line : 1m
  • Relay: Connection : AC 240V 2.5A C300 at least AC/DC 24V 20mA
  • Relay: Mechanical service life : Approx. 1 million switching cycles
  • Interface : Diagnose port (DP)
  • Protection class acc. To EN 60529 : IP00
  • Connection type : 6.3mm flat plugs (L1-L3, L and N), push-in spring terminals, 0.25-0.75mm2
  • Housing material : PA glass-fibre-reinforced
  • Mounting : Screw mounted
  • Dimensions : Refer to dimensions in mm
  • Weight : Approx. 150g
  • Check base : EN 61000-6-2, EN 61000-6-3 EN 61010-1 Overvoltage category II Pollution level 2
  • Approval : ULFileNo.E75899 cURus