1
Hi, Guest!

  LOKASI :  JAKARTA UTARA

  AKTIVITAS :  04/09/2019

BAGIKAN :   

Bagikan :
Masukan Data Diri Anda
Nama harus diisi !
Email harus diisi !
Format email harus someone@example.com !
Beyond Imagination, Listening, Solving & Delivering.

KRIWAN INT69 TML Diagnose Article-Nr.: 22 A 495

Update Terakhir
:
19 / 01 / 2019
Min. Pembelian
:
1 Unit
Harga
CALL
Bagikan
:
Beyond Imagination Vendor

Detail KRIWAN INT69 TML Diagnose Article-Nr.: 22 A 495

KRIWAN INT69 TML Diagnose Article-Nr.: 22 A 495

Product details :
  • Application : Medium and large semi-thermal piston compressors with oil pumps
  • Functions : Motor temperature static, Motor temperature dynamic, Discharge gas, Lock-out, differential pressure, Short circuit or open circuit
  • Supply voltage : AC 115-230V
  • Permitted ambient temperature : -30...+70°C
  • Temperature measuring circuits: Type : 1-2 AMS sensors in series alternative 1-9 PTC sensors acc. to DIN 44081, DIN 44082 in series
  • Temperature measuring circuits: R_25, total : <1.8kΩ
  • Temperature measuring circuits: R_trip, static : 4.5kΩ ±20%
  • Temperature measuring circuits: R_reset : 2.75kΩ ±20%
  • Temperature measuring circuits: Max. length connection line : 30m
  • Short circuit monitoring system PTC : Typically <30Ω
  • Input, operating recongnition motor: Lower limit : AC 100V at 20Hz to 175V at 90Hz
  • Input, operating recongnition motor: Upper limit : AC 690V ±15%
  • Switching frequency overstepping : 3 switch-offs in 30s
  • Operating with frequency converters : Suitable
  • Reset delay: Motor temperature static : 5min ±1min
  • Reset delay: Motor temperature dynamic : 10min ±2min, 60min ±12min, Locked
  • Reset delay: Discharge gas temperature : 10min ±2min, Verriegelt
  • Reset delay: Switching frequency overstepping : 5min ±1min
  • Resetting the lock or the reset delay : Main reset >5s or reset by keyboard only possible if there is no error current
  • External button: Designed for : Potential-free normally open contact (typ. 5V, 1mA)
  • External button: Max. length connection line : 1m
  • Relay: Connection : AC 240V 2.5A C300 at least AC/DC 24V 20mA
  • Relay: Mechanical service life : Approx. 1 million switching cycles
  • Interface : Diagnose port (DP)
  • Protection class acc. To EN 60529 : IP00
  • Connection type : 6.3mm blade terminal (operating recognition), push-in spring terminals 0.25-0.75mm2
  • Housing material : PA glass-fibre-reinforced
  • Mountin : Screw mounted
  • Dimensions : Refer to dimensions in mm
  • Weight : Approx. 200g
  • Check base : EN 61000-6-2, EN 61000-6-3 EN 61010-1 Overvoltage category II Pollution level 2
  • Approval : UL File No. E75899 cURus
Tampilkan Lebih Banyak
cv. revianes utama indojaya
cv. revianes utama indojaya

CV. REVIANES UTAMA INDOJAYA

PREMIUM GOLD 1 Tahun
JL. PEGANGSAAN DUA, GADING ARCADIA Blok H No. 6, JAKARTA UTARA
Indonesia 14250
JAKARTA UTARA
04 / 09 / 2019
Hubungi Kami

Detail KRIWAN INT69 TML Diagnose Article-Nr.: 22 A 495

KRIWAN INT69 TML Diagnose Article-Nr.: 22 A 495

Product details :
  • Application : Medium and large semi-thermal piston compressors with oil pumps
  • Functions : Motor temperature static, Motor temperature dynamic, Discharge gas, Lock-out, differential pressure, Short circuit or open circuit
  • Supply voltage : AC 115-230V
  • Permitted ambient temperature : -30...+70°C
  • Temperature measuring circuits: Type : 1-2 AMS sensors in series alternative 1-9 PTC sensors acc. to DIN 44081, DIN 44082 in series
  • Temperature measuring circuits: R_25, total : <1.8kΩ
  • Temperature measuring circuits: R_trip, static : 4.5kΩ ±20%
  • Temperature measuring circuits: R_reset : 2.75kΩ ±20%
  • Temperature measuring circuits: Max. length connection line : 30m
  • Short circuit monitoring system PTC : Typically <30Ω
  • Input, operating recongnition motor: Lower limit : AC 100V at 20Hz to 175V at 90Hz
  • Input, operating recongnition motor: Upper limit : AC 690V ±15%
  • Switching frequency overstepping : 3 switch-offs in 30s
  • Operating with frequency converters : Suitable
  • Reset delay: Motor temperature static : 5min ±1min
  • Reset delay: Motor temperature dynamic : 10min ±2min, 60min ±12min, Locked
  • Reset delay: Discharge gas temperature : 10min ±2min, Verriegelt
  • Reset delay: Switching frequency overstepping : 5min ±1min
  • Resetting the lock or the reset delay : Main reset >5s or reset by keyboard only possible if there is no error current
  • External button: Designed for : Potential-free normally open contact (typ. 5V, 1mA)
  • External button: Max. length connection line : 1m
  • Relay: Connection : AC 240V 2.5A C300 at least AC/DC 24V 20mA
  • Relay: Mechanical service life : Approx. 1 million switching cycles
  • Interface : Diagnose port (DP)
  • Protection class acc. To EN 60529 : IP00
  • Connection type : 6.3mm blade terminal (operating recognition), push-in spring terminals 0.25-0.75mm2
  • Housing material : PA glass-fibre-reinforced
  • Mountin : Screw mounted
  • Dimensions : Refer to dimensions in mm
  • Weight : Approx. 200g
  • Check base : EN 61000-6-2, EN 61000-6-3 EN 61010-1 Overvoltage category II Pollution level 2
  • Approval : UL File No. E75899 cURus
Tampilkan Lebih Banyak