KRIWAN INT369 KA Diagnose Article-Nr.: 22 A 278 S25
Product details :
- Application : Compressors with individually led out PTC sensors
- Functions : Motor temperature static, Supply voltage
- Supply voltage : AC 120/240V
- Undervoltage limits : 85V (120V-Netz) / 170V (240V-Netz)
- Permitted ambient temperature : -40...+70°C
- Temperature measuring circuits: Type : 3 separate inputs for PTC sensors acc. to DIN 44081, DIN 44082
- Temperature measuring circuits: R_trip, static : 13kΩ ±3kΩ
- Temperature measuring circuits: R_reset : 3.25kΩ ±0.5kΩ
- Temperature measuring circuits: Max. length connection line : 30m
- Reset delay: Motor temperature static : 2min ±20s
- Reset of reset delay : Activation of the reset input only possible if there is no error current
- Relay: Connection : Refer to wiring diagram Max. 2.5A C300
- Relay: Mechanical service life : Approx. 1 million switching cycles
- Interface : Diagnose port (DP)
- Protection class acc. To EN 60529 : IP00
- Connection type : 6.3mm flat plugs
- Housing material : PA glass-fibre-reinforced
- Mounting : Screw mounted
- Dimensions : Refer to dimensions in mm
- Weight : Approx. 200g
- Check base : EN 61000-6-2, EN 61000-6-3 EN 61010-1 Overvoltage category II Pollution level 2
- Approval : UL File No. E75899 cURus
- Reset delay : 2min ±20s